Skip to content
Version 2026.21

Equipment ​

A smart-object symbol for process equipment — tanks, heat exchangers, fans, conveyors, line items and separators — chosen from a library by name.

In Studio ​

In Studio, double-click Equipment in the Process category of the Components panel. It is added to the open view, where you can drag it into place.

When to use ​

Use Equipment for a plant item that has no component of its own. It shows Stopped / Running / Fault like Pump does, and a vessel can also show a liquid level.

Properties ​

PropertyTypeDefaultDescription
ValueString(none)Same value contract as Pump's Value.
Symboltank_vertical, tank_horizontal, tank_cone_bottom, tank_open_top, silo, hopper, heat_exchanger_shell_tube, plate_heat_exchanger, heater_coil, fan, blower_centrifugal, compressor, agitator, belt_conveyor, screw_conveyor, bucket_elevator, rotary_airlock_feeder, check_valve, relief_valve, y_strainer, flow_meter, static_mixer, filter, cyclone, centrifuge, dryertank_verticalWhich drawing to show. See the symbol table below.
Symbol Typesimple, pnid, mimicsimpleThe drawing variant: simple, pnid or mimic. A symbol that has no drawing for the chosen variant shows its P&ID drawing.
LabelString(none)The caption shown below the symbol. Left blank, it shows the symbol's own name.
Show Captiontrue, falsetrueShows or hides the caption (the name and state word) under the symbol. Off also gives that height back to the drawing — use it when a separate label template sits beside the symbol.
Level %String(none)Percent full, 0–100. Used only by vessel symbols; values outside the range are clamped and a non-number draws no liquid.
Orientationright, down, left, uprightWhich way the symbol faces: right (as drawn, default), down, left, or up. Vessels and floor-standing symbols ignore it.
Animatetrue, falsetrueSame contract as Motor's Animate. Rotating symbols only turn while Running and Animate is on.
Stopped ColorColor#808080The body color while Stopped. Defaults to the HMI palette's stopped-state color.
Running ColorColor#FFFFFFThe body color while Running. Defaults to the HMI palette's running-state color.
Fault ColorColor#E12D39The body color while Fault. Defaults to the HMI palette's priority-1 alarm color.
Liquid ColorColor#5A6470The color of the liquid in a vessel. Defaults to the HMI palette's liquid color.

Binding ​

Click Bind… on the Value property and bind it to a tag or an expression to drive the live value.

This binding is read-only — the component never writes to the tag.

Level % is a second, independent read-only binding for vessel symbols.

Symbols ​

CategorySymbol idsNotes
Vesselstank_vertical, tank_horizontal, tank_cone_bottom, tank_open_top, silo, hopperShow Level %. Orientation is ignored.
Heat transferheat_exchanger_shell_tube, plate_heat_exchanger, heater_coil
Rotatingfan, blower_centrifugal, compressor, agitatorThe rotor turns while Running.
Conveyingbelt_conveyor, screw_conveyor, bucket_elevator, rotary_airlock_feederThe screw and the airlock rotor turn while Running.
Valves and linecheck_valve, relief_valve, y_strainer, flow_meter, static_mixer
Separationfilter, cyclone, centrifuge, dryer